03 Aug,2020 UTC+8 Views:
In order to ensure the high quality coal vertical mill, some of the more dangerous faults in the operation of the coal mill equipment must be understood:
1. Excessive coal spillage
This is a dangerous situation. A large amount of coal overflow will block the discharge of pebble and coal, and accumulate in the hot air chamber, causing the hidden danger of fire in the mill. At the same time, it will damage the slag cleaning device and block the hot air from entering the mill body.
Solution: timely adjust the inlet and outlet control system of the coal vertical mill, and adjust the air intake inside the vertical mill and the height of the vertical mill retaining ring.
2. The vertical mill continues to run when the outlet temperature is lower than the specified value
This is a dangerous working condition. If the coal is not sufficiently dried, it will be adsorbed inside the vertical mill and the pulverized coal pipe, which will block the pulverized coal pipe or cause the vertical mill and the pulverized coal pipe to catch fire.
Solution: Reduce the coal feed rate, maintain the outlet temperature, and re-check the ventilation control system.
3. The vertical mill runs under conditions where the outlet temperature is higher than the specified value
This is a dangerous working condition. The high outlet temperature drives the volatiles to escape from the coal, thereby increasing the potential for fire. The specified value of the outlet temperature of the vertical mill should be determined according to the characteristics of the coal.
Solution: Check whether the hot air damper is faulty: close the hot air door in time and stop grinding for repair.