28 Mar,2019 UTC+8 Views:
In the vertical roller mill, the reducer is called the “heart” of the vertical mill. The advanced reducer design can not only provide the load of the vertical mill, but also provide the output and service life of the mill, thus achieving energy saving and emission reduction. effect. However, due to the long running time of the vertical mill and the large wear, the reducer will have some faults during operation. If it is not processed in time, it will affect the normal operation of the mill.
How to judge whether the gearbox is in good working condition during use:
1. The temperature of each temperature measuring point of the reducer is within the normal range, and the heat balance is reached.
2. The oil pressure is normal, and the records are within the normal range, and there is no large fluctuation.
3. No oil leakage or water leakage, no abnormal noise during operation, and no alarm signal for each alarm switch.
4. The interlocking device is in good condition. If there is a fault, it can automatically stop and alarm in time.
5. There is no metal shavings in the double filter and magnetic filter.
Reasons and solutions for noise and vibration of the reducer:
1. Gear or bearing damage; method: open the cover to check or replace the damaged parts
2, overload or impact load; method: check whether the mill or motor is faulty
3, the bearing is loose; method: check and tighten the fastening bolt of the bearing cap
4. Grinding machine end or motor center line offset; Method: Correct the center line and check the offset reason
Daily maintenance of vertical mill reducer:
1. Regularly check whether the base of the reducer of the vertical mill, the seals, the drive shaft, etc. are normal.
2. If it is used normally, always check the oil level of the lubricating oil (can be observed through the oil window), the high temperature of the lubricating oil should be less than 85 °C. When the oil temperature rises abnormally, abnormal noise is generated, etc., it is necessary to stop the inspection immediately and remove the fault before continuing to use.
3. Replacement of new parts must be officially used after running and load testing.
4. Do not gravity hammer the outer casing of the vertical mill to avoid damage.